Fire Alarm Systems | Addressable and Conventional | YANSIS
Products

Addressable Fire Alarm Panel

Addressable Fire Alarm Panel

Product Code: YNS-ADR-003

YANSİS Addressable Fire Alarm Panel is an intelligent fire alarm control solution that provides high-level safety in large-scale projects with advanced monitoring and point-based detection features.

Where to Buy

YANSİS Addressable Fire Alarm Panel is an advanced control panel designed to provide centralized management for addressable fire alarm systems. Thanks to the ability to monitor all connected devices individually, fire, fault, and status information can be tracked with point-based precision.

With its advanced scenario management, fast alarm processing capacity, and user-friendly interface, it delivers high performance in production facilities, hospitals, shopping centers, hotels, and large-scale commercial projects.

Its addressable infrastructure enables detectors, manual call points, modules, and other field devices within the system to be controlled from a single center. This structure significantly reduces response time while enhancing operational safety.

With its reliable operating structure, flexible system integration, and scalable infrastructure, the YANSİS Addressable Fire Alarm Panel provides professional solutions for modern fire safety projects.

 

In an addressable panel every device carries a unique address on the loop. The panel communicates with each device individually, so alarm information arrives not as "alarm in zone 3" but as "Loop 2, Address 47 — Third Floor Operating Theatre Corridor, Optical Smoke Detector." The search phase disappears.

Capacity planning is set by loop count and devices per loop. Because a single loop can carry hundreds of devices, one cable run replaces the separate run each zone requires in a conventional system. In large buildings the saving in cable and electrical labour covers much of the difference in panel cost. Spare capacity is left on loops at design stage, so adding devices later does not require new cabling.

Loops are planned to align with fire compartments and segmented with short-circuit isolators. Cable damage in one compartment disables only that section while the rest of the loop continues to operate. A short on a conventional circuit blinds the entire zone.

The panel's real capability is scenario management. A cause-and-effect matrix is built at address level: a specific detector can close fire dampers, recall lifts to the evacuation floor, start smoke extraction, release door holders and activate the public address system. Phased alerting and verification delays are defined in the same matrix — decisive in hotels and hospitals where unnecessary evacuation is costly.

During commissioning every device is tested individually, addresses are mapped and scenarios verified. The panel maintains an event log; reviewing this log at quarterly service falls under TS CEN/TS 54-14. Control panels fall under TS EN 54-2 and power supplies under TS EN 54-4.

System Type Addressable Fire Alarm System
Loop Capacity 1-2 Loop (depending on model)
Display Type LCD Display
Alarm Management Point-Based Alarm Monitoring
Communication Digital Addressing
Power Supply Type Built-in Power Supply
Mounting Type Wall Mounted
Integration Support for sirens, detectors, modules, and repeater panels

Similar Products